Fuel Gas Booster Compressors for Gas Turbines | USP&E

New Gas Turbines

Fuel Gas Booster Compressors for New Gas Turbines

A gas turbine can only burn fuel that arrives at the right pressure. The combustor sits downstream of the turbine’s own air compressor, so the fuel gas must be pushed in against that pressure, with enough margin left over for the control valves and nozzles to do their job. If the pipeline cannot supply that pressure all year round, a booster compressor has to make up the difference.

This guide explains how to tell whether a new turbine needs fuel gas compression, how the pressure and flow are worked out, which compressor types are used and how to design the system so that it does not become the most common cause of trips on the site.

Why fuel gas pressure matters

The required pressure at the turbine fuel skid is set by the pressure inside the combustor, plus losses across the fuel control valves, filters and nozzles, plus a margin for transients. Combustor pressure is close to compressor discharge pressure, so it rises with the turbine’s pressure ratio. As an illustration, a machine with a pressure ratio near 30 at sea level has a combustor pressure of roughly 30 bar absolute, and the fuel system needs a supply comfortably above that.

Aeroderivative turbines usually run higher pressure ratios than heavy industrial frames, so they tend to need higher fuel gas pressure. Our comparison of aeroderivative and industrial turbines for data centers covers this and other differences. The exact figure for any unit comes from the manufacturer’s fuel specification, which should be part of the purchase documents.

Read the pipeline pressure carefully

The supply pressure that matters is not the typical pressure in the pipeline but the minimum the gas company will commit to at the delivery point. On many networks pressure drops on cold days, when heating demand is high, which is also when a campus may be relying most on its own plant. Ask for the contractual minimum, the historical low, and any planned changes to the network.

Then subtract the pressure lost through the metering station, the pressure regulator, filters and the piping run to the turbines. If what is left falls below the turbine requirement at any point in the year, compression is needed. If it falls below only on rare occasions, the owner may choose to accept reduced output on those days instead, but that decision should be explicit and written into the plant’s operating limits.

Working out the flow

Compressor flow follows from the turbine’s fuel use. Multiply the electrical output by the heat rate to get fuel energy per hour, then divide by the gas heating value. For a 40 MW unit at a heat rate of about 9,500 kJ per kWh, fuel energy is roughly 380,000 MJ per hour. With pipeline gas at about 36 MJ per normal cubic metre, that is close to 10,500 normal cubic metres per hour.

Size the compressor for the highest flow case, usually full load on the coldest day when turbine output is highest, and for the number of turbines it serves. Add margin for heating value variation; our guide to fuel flexibility for turbine buyers explains how gas composition can change. These figures are illustrative arithmetic; the real design uses the manufacturer’s performance data at site conditions.

Choosing a compressor type

Reciprocating compressors handle high pressure ratios and varying conditions well and are common on smaller and mid-sized plants. They need careful pulsation control, and their wearing parts such as valves and rings require regular service. Oil-flooded screw compressors suit moderate pressure lifts and have fewer wearing parts, but they need effective oil separation so that no lubricant reaches the turbine.

Centrifugal compressors suit large, steady flows and are often driven by electric motors on large plants. They are compact for their capacity but less tolerant of wide changes in flow and need a recycle line for surge protection. The choice depends on pressure lift, flow range, maintenance capability on site and the electrical supply available to drive them.

Redundancy and parasitic load

If every turbine depends on a single compressor, that compressor is a single point of failure for the plant. Common arrangements are two units each sized for full flow, or three units each sized for half. On a data center plant, the compressor redundancy level should match the turbine redundancy level, otherwise the spare turbines offer less protection than expected.

Compression also consumes power. Depending on the pressure lift, booster compressors can take a few percent of the plant’s output, which reduces net output and raises the effective heat rate. Include that parasitic load in the plant performance figures and in any guarantee, and plan capital spares for the compressors alongside the turbines. Our page on capital spares for new turbines covers the wider spares list.

Conditioning gas after compression

Compressing gas heats it, so aftercoolers bring it back to a manageable temperature. Cooling, however, can drop heavier hydrocarbons or water out as liquid, and liquids reaching the combustor cause damage and trips. A coalescing filter after the compressor, followed by a fuel gas heater that keeps the gas a safe margin above its dew point, is the usual answer.

Lubricated compressors add another risk: oil carryover. Filters rated for oil removal, regular inspection and differential pressure alarms protect the turbine. Fuel quality problems of this kind are among the common causes of gas turbine trips, and most can be prevented with a properly designed conditioning train.

Holding pressure steady during load changes

When a turbine takes a load step, its fuel flow jumps within seconds. If the compressor and its controls cannot keep pace, pressure at the turbine sags, and the fuel valve may run out of authority. On a data center plant with fast load swings, this can become the limit on how quickly the turbines respond.

A buffer volume between the compressor and the turbines, well tuned pressure control, and recycle valves that close quickly as demand rises all help. The dynamic behaviour should be checked in commissioning with real load steps, not only at steady load, and the compressor control logic should be included in the plant controls review.

When compression can be avoided

The simplest way to remove the compressor is to obtain a higher pressure supply. A dedicated lateral from a transmission pipeline often delivers pressure high enough to feed turbines directly after metering and regulation. That option involves a longer pipeline and its own permits, but it removes rotating equipment, power use and a maintenance burden from the plant.

Choosing a turbine with a lower pressure requirement is another route, though it may trade off efficiency or output. The comparison belongs early in the project, together with layout and site choices. Our overview of turbine plants for data centers sets out how fuel supply fits with those decisions.

About the authors

This guide comes from the USP&E gas turbine balance of plant engineering team. USP&E is an EPC and O&M contractor, not a broker, with 150+ power projects in 45+ countries, 25,000 MW contracted since 2002 and 24+ years in the field. Our approach to complete plant delivery is described on the power plant EPC projects page.

Offices: Colorado Springs (1755 Telstar Dr, Suite 300), Knoxville (800 S Gay St, Suite 700), London (162-168 Regent Street), Johannesburg (22 Kildoon Rd, Bryanston), Cape Town (31 Brickfield Road, Woodstock) and China (No. 1 Ningzhou Road, Wuxi). Regions: USA | AFRICA | UK | UAE | CHINA. ISO 9001 and ISO 45001 certified.

Fuel gas compressor questions

Does every gas turbine need a fuel gas compressor?

No. A compressor is needed only when the minimum pipeline pressure, after metering and regulation losses, is below the turbine’s fuel supply requirement.

What fuel gas pressure does a gas turbine need?

Enough to exceed combustor pressure plus valve and nozzle losses and a margin. It rises with pressure ratio and is set in the manufacturer’s fuel specification.

Which compressor type is used for turbine fuel gas?

Reciprocating, oil-flooded screw and centrifugal compressors are all used, chosen on pressure lift, flow range and maintenance capability.

How much power does a fuel gas compressor use?

It depends on the pressure lift and flow, but it can be a few percent of plant output, which should be counted in net output figures.

Why is gas heated after compression?

Cooling after compression can drop liquids out of the gas. Filtering and then heating it above its dew point keeps liquids out of the combustor.

How can a project avoid fuel gas compression?

By securing a higher pressure supply, such as a dedicated lateral from a transmission pipeline, or by choosing a turbine with a lower pressure requirement.

Check your fuel gas supply

Send the pipeline pressure data, gas analysis and the turbines you are considering, and our engineers will assess whether compression is needed and how to arrange it.

If a document set is easier than a conversation, send it to info@uspeglobal.com or upload a summary through the turbine enquiry page; to talk it over, dial +27 10 822 2324. New units and available packages are listed in our natural gas turbine listings.


Where we operate

USA | AFRICA | UK | UAE | CHINA

USP&E United States

Colorado Springs Office: 1755 Telstar Dr, Suite 300

Knoxville Office: 800 S Gay St, Suite 700

USP&E South Africa

Johannesburg Office: 22 Kildoon Rd, Bryanston

Cape Town Office: 31 Brickfield Road, Woodstock

USP&E United Kingdom

London Office: 162-168 Regent Street

USP&E China

China Office: No. 1, Ningzhou Road, Wuxi

Call:+27 10 822 2324  |  E:info@uspeglobal.com

ISO Certifications
ISO9001ISO45001

Powering Possibility. Built for the Frontier.
Full-service EPC & O&M. Not a broker.

© 2026 USP&E · New Gas Turbines is part of USP&E